Pipe Bursting for Sewer Lines: Sizing, Material Selection, and What to Expect on Site
Home »
Pipe bursting replaces a failing sewer line without trenching the whole yard. A crew pulls a bursting head through the old pipe, which breaks it outward into the surrounding soil, and a new pipe follows right behind. Three decisions shape every job: how big the new pipe should be, what it should be made of, and what happens on site. This guide covers all three so you can ask better questions before anyone digs.
The Short Answer
- Size. Most jobs replace the old pipe with the same size or a larger one. Industry guidance says upsizing by up to about 30% is common, and up to three pipe sizes has been done.
- Material. HDPE is the most common replacement pipe. Its fused, jointless length is the main reason.
- On site. Expect a camera inspection first, two access pits, a temporary loss of sewer service, and testing before the new line goes into use.
How Pipe Bursting Works
A cone-shaped bursting head is attached to the front of the new pipe. A cable or rod runs through the old pipe to a pulling machine at the far end. As the machine pulls, the head fractures the old pipe and pushes the pieces into the soil while the new pipe is drawn into the space it leaves. The EPA’s pipe bursting fact sheet describes this process, and NGI describes the same one on its sewer pipe replacement page: the old pipe is broken apart and a new line is inserted behind it. NGI says it pulls new HDPE pipe through the old line on its trenchless sewer repair work.
Bursting heads come in static and dynamic types. Dynamic heads add pneumatic or hydraulic force and are often needed in difficult pipe or soil, but they can move the ground around them. EPA says static heads are preferred where pipe and soil conditions don’t suit dynamic ones.
Sizing the New Pipe
![]()
Same size or bigger?
The most common job is a size-for-size replacement. But EPA says that from a practical and value standpoint, it’s considered advisable to go at least one size larger, since that adds capacity if loads grow later. Bursting is also the trenchless method that gives the biggest gain in capacity, because lining the inside of a pipe shrinks its inside diameter. NGI explains when this applies in its guide to when pipe bursting is necessary.
Sometimes the size is decided for you. In one Virginia project described by EPA, crews replaced 6-inch clay pipe with the county’s minimum 8-inch size. Ask your utility or inspector what the minimum is where you live.
How far can you go?
The Trenchless Technology Center’s guidelines, written for the U.S. Army Corps of Engineers, say the most common job is size-for-size or upsizing up to three sizes, such as 8-inch to 12-inch. They add that upsizing by up to 30% of the original diameter is common and that larger increases have been done. But every extra size takes more energy, moves more ground, and slows the job. At upsizes approaching 100%, the report notes the head can ride along the bottom of the old pipe and plow through the top.
What limits upsizing
| Factor | Why It Limits Upsizing |
|---|---|
| Soil and backfill | Densely compacted soil and backfill need more force and spread ground movement farther (EPA) |
| Depth | Shallow pipe pushes ground movement upward, which can cause heave at the surface (EPA, TTC) |
| Nearby utilities | The bursting head should not pass closer than 2.5 feet to buried pipes or 8 feet to sensitive structures (TTC) |
| Pipe diameter | Small pipes can be harder to burst than larger ones. An 8-inch pipe is easier than a 4-inch pipe (TTC) |
| Groundwater | Bursting below the water table is harder because water pressure builds around the head (EPA, TTC) |
One practical tip: ask for the inside diameter of the finished pipe, not just its nominal size. A thicker wall leaves less room inside.
Choosing the New Pipe Material
The TTC guidelines say HDPE and MDPE are the most common replacement materials. EPA adds that one lateral replacement system it describes, from TRIC Tools, always uses HDPE because of its flexibility and durability. Here is how the main options compare.
| Replacement Pipe | Why It's Used | Watch-Outs |
|---|---|---|
| HDPE (and MDPE) | The most common choice. Sections are heat-fused into one continuous, flexible pipe with no joints to pull apart | Needs room to lay out and fuse the pipe; expands and contracts with temperature |
| Fusible PVC | Also fused into a continuous length; some contractors use it alongside HDPE | Ask the contractor why it fits your project |
| PVC with locking joints | A possible substitute when there isn't space to fuse and string the pipe | Joints must withstand the pull; not the standard choice |
| Clay, concrete, or flush-joint ductile iron | Used on some larger or special projects | Installed in segments, which slows the job; rare for homes |
Wall thickness and sharp fragments
Pieces of broken clay or cast iron can be sharp and may scratch the new pipe. For gravity sewer lines, the TTC report says this is much less of a concern than for pressure pipe, and that a slightly thicker wall can allow for scarring. It suggests an extra 10% of thickness, and says one or two steps lower on the DR scale (a thicker wall) could be enough. The report also says long-term loading, not pull strength, usually sets the wall thickness for sewer pipe. Many specifications ask for a light-colored pipe so a camera can see the inside clearly afterward.
What about the old pipe?
The old pipe matters just as much as the new one. The TTC report rates the common materials this way:
- Clay: a good candidate. It is brittle and fractures easily.
- Cast iron: a good candidate, but repair clamps and fittings can cause problems.
- Plain concrete: a good candidate. Thick concrete encasement or repairs can make it harder.
- Asbestos cement: often burstable, but the pipe class matters, and asbestos-containing pipe has its own handling rules. If your line may be asbestos cement, ask your contractor early.
- Ductile iron and steel: not good candidates. They are replaced by splitting, not bursting.
- PVC and other plastics: may need a mix of bursting and splitting, according to TTC. EPA says HDPE host pipe generally isn’t suited to bursting.
What the Camera Must Check Before You Choose Bursting
![]()
Bursting works best when the path is clear. A camera inspection and hydro jetting come first, and NGI says every trenchless repair starts with the camera. The TTC report lists what can stop or slow a burst:
- Collapsed sections. A collapse can block the head. Many obstructions can be solved with a small local dig, but a partly collapsed pipe is often unsuitable.
- Metal repair clamps. Ductile material is hard to burst.
- Concrete around the pipe. Uneven concrete can steer the head off course.
- Thick root balls. Roots wrapped tightly around the pipe absorb shock.
- Big sags. A sag deeper than about half the pipe diameter should be fixed with a local excavation first.
- Nearby utilities and certain soils. Expansive soils, close utilities, and soil below the water table all raise the difficulty.
If the pipe is mostly intact, lining may be the better fit. See NGI’s guide to when trenchless lining gives way to full replacement, or its trenchless pipe lining page.
What to Expect on Site
NGI says bursting needs only two small access points and typically takes less than a day or two. Your timeline depends on the length of the line and any obstructions. EPA gives a typical bursting rate of about 100 feet per hour, but that is only the pulling step. Here is the usual order of work.
Before anyone digs: Georgia law requires a call to Georgia 811 before mechanized digging, at least 48 hours and no more than 10 working days ahead, and the service is free. Georgia 811’s own page also states the lead time as three business days, so plan for at least three and confirm on georgia811.com. Your contractor should file the dig ticket. Ask them for the ticket number.
You can read more on the Georgia 811 site.
- Camera and cleaning. The crew inspects and cleans the line to learn its material, size, and condition.
- Locating. Public utilities are marked after the dig ticket. Tell the crew about private lines too, such as irrigation or outdoor lighting.
- Digging two pits. An entry pit and an exit pit let the new pipe in and the pulling gear out. Pits are usually placed at each end of the run.
- Taking the line out of service. EPA says the segment being replaced must be taken out of service. Plan on limited water use while the line is down.
- Fusing the new pipe. HDPE arrives in sections and is heat-fused into one long pipe in your yard. TTC says this is done before bursting so every joint can be checked, and that the space to lay it out limits the run length.
- Bursting and pulling. EPA notes that pneumatic bursting can create quite noticeable vibration at the surface. The TTC study found it very unlikely to damage anything more than a few feet from the head.
- Resting and testing. TTC says the new pipe should rest, normally at least four hours, before reconnection so it can cool and relax. Crews then test the pipe. TTC describes a low-pressure air test of the joints and a smoke test of the lateral connections.
- Reconnecting and restoring. The line is tied in and returned to service, and the pits are backfilled. A final camera run is a common request.
How you can help
- Clear a path to the cleanout and the work area, including space for the long pipe string.
- Move vehicles and anything that could be in the way.
- Tell the crew about past repairs, earlier digging, and private underground lines.
- Keep pets and children away from the pits and equipment.
- Ask for the final camera footage and test results.
Questions to Ask Your Contractor
- What size is the new pipe, and why that size?
- What material and wall thickness will you use, and how are the joints made?
- How will you check for obstructions before and during the burst?
- What happens if the head gets stuck? TTC says an unplanned dig may be needed, so ask who pays.
- How will lateral connections be reconnected and tested?
- Will I get video and test results when the job is done?
Frequently Asked Questions
Can pipe bursting make my sewer pipe bigger?
Yes. Bursting is one of the few trenchless methods that can increase pipe size. Upsizing by up to about 30% is common, and up to three sizes has been done, but larger increases take more force and move more ground.
What material is used for pipe bursting?
HDPE is the most common replacement pipe. Its sections are fused into one continuous, flexible pipe with no joints to pull apart. Other materials are possible when conditions call for them.
How long does pipe bursting take?
NGI says bursting takes less than a day or two with two small access points. EPA gives a typical pulling rate of about 100 feet per hour. Obstructions, fusing time, and testing can add time.
Can you burst a collapsed pipe?
Sometimes. A collapse can block the bursting head, and a partly collapsed pipe is often unsuitable. Many obstructions are solved with a small local dig. A camera inspection shows what you have.
Will pipe bursting damage my yard or nearby pipes?
Bursting needs two pits, so you will have some digging, but far less than a full trench. Bursting moves the ground around the pipe, and shallow pipes can cause surface heave. Crews should locate nearby utilities first and keep the head well away from them.
Is pipe bursting better than lining?
It depends on the pipe. Lining suits pipe that is still mostly intact. Bursting suits pipe that is badly broken or too small, because lining shrinks the inside diameter while bursting can enlarge it.
What affects the cost of pipe bursting?
EPA lists the main factors: pipe diameter and material, length, depth, the number of access points, nearby utilities, bypass needs, how many service connections must be reconnected, and ground conditions. NGI’s pipe lining and repair cost page has more, and a camera inspection is the first step to an accurate quote.
The best pipe bursting jobs are planned before the first pit is dug. Know the old pipe’s material and condition, choose a new size and material for good reasons, and ask what happens on site. If you want a straight answer on whether bursting fits your line, start with a camera.
NGI Trenchless Pipe & Sewer Repair: Trenchless Sewer and Pipe Rehabilitation in Metro Atlanta
NGI Trenchless Pipe & Sewer Repair is based in Woodstock and Canton, GA. It holds Georgia Utility Contractor license UC 302559 and has NASSCO-certified professionals on its team. Services include CCTV inspection, hydro jetting, cured-in-place pipe lining, and pipe bursting.
Call (404) 860-2022 to schedule an inspection or ask about your sewer line.
Planning a sewer line replacement?
Start with a camera inspection. We’ll show you the pipe’s condition and help you choose between lining and bursting.
Schedule a Camera Inspection | (404) 860-2022