Why Facilities and Public Works Departments Choose Pipe Bursting for Full-Line Replacement

Home » Why Facilities and Public Works Departments Choose Pipe Bursting for Full-Line Replacement

Facilities and public works teams choose pipe bursting when a buried pipe has to be replaced, not patched, and digging up the entire line isn’t acceptable. A bursting tool is pulled through the old pipe, breaks it outward into the surrounding soil, and pulls a new pipe into the same path, so the work needs small access pits instead of a continuous trench. Teams pick it for a handful of practical reasons: it’s a true replacement, the old pipe’s condition doesn’t limit it, it can increase capacity, and it keeps surface disruption small. This guide explains each one using EPA’s technical guidance, plus where bursting is a poor fit.

How Pipe Bursting Works

According to EPA’s Water Technology Fact Sheet on pipe bursting, a hydraulic or pneumatic expansion head is pulled through the existing pipeline, usually by a cable and winch. As it moves, it pushes the old pipe outward until it breaks apart, making room for the new pipe. The bursting device pulls the new pipeline behind it, so the void left by the old pipe is filled immediately. EPA notes that the traditional alternative, dig-and-replace, means excavating the entire length of the pipeline.

Here’s a snapshot of EPA’s numbers. The fact sheet dates to 2006, so treat the figures as general guidance and let your engineer set project-specific parameters.

ConditionWhy It Matters
Obstructions along the pipeThey increase friction or can block the path of the expansion head and replacement pipe
Metallic point repairsDuctile material is difficult to burst
Adjacent pipes or utility linesOther utilities may mean the bursting can't deviate from the existing alignment without risking damage
Soil below the water tableSaturated soil raises pressure around the bursting head and groundwater can flow toward open pits
Rocky or sandy soilsEPA doesn't recommend bursting in soils that aren't compressible
Shallow pipeGround heave can occur, and dynamic heads can move surrounding ground enough to damage nearby structures
Asbestos-cement (AC) pipeEPA says bursting or breaking AC pipe makes it friable and doesn't comply with the Asbestos NESHAP

Why Facilities and Public Works Teams Choose It

1. It’s a true replacement, not a repair

Lining restores a pipe from the inside and depends on the old pipe as a host. Bursting installs a new pipe, so you aren’t relying on a failing one. That’s often what an asset manager wants when a line is at the end of its life. NGI offers both methods; its sewer pipe replacement page explains how bursting and trenchless pipe lining fit different conditions.

2. The old pipe’s condition doesn’t limit it

EPA says the condition of the existing pipe doesn’t affect the ability to burst, as long as the pulling cable can be inserted. That matters when a line is shattered or partly collapsed. EPA’s example is Fairfax County, Virginia, where about 4,000 feet of 1940s clay pipe was replaced after CCTV showed much of it had completely shattered. Dig-and-replace wasn’t feasible because of residents’ concerns about disruption, and pipe bursting was chosen because no other trenchless method suited the shattered pipe.

3. It can add capacity

EPA notes that lining reduces a pipe’s inside diameter and capacity. Bursting replaces the pipe size-for-size or larger, and EPA says it typically yields the largest increase in hydraulic capacity of any trenchless sewer rehabilitation method. It also advises that, from a practical and value engineering standpoint, going up at least one pipe size is usually advisable to allow for increased loading over time. The amount of up-sizing possible depends on the compactness of the surrounding soil, and larger up-sizings take more energy and cause more ground movement.

4. It keeps surface disruption small

EPA says trenchless rehabilitation can reduce traffic and pedestrian detours, minimize tree removal, decrease construction noise, and reduce emissions from construction equipment compared with dig-and-replace. For a campus, a plant, a hospital, a school, or a residential street, that can be the deciding factor.

5. It shrinks the work zone

Confining work to a limited number of access points reduces the area where safety concerns have to be identified and secured, according to EPA. A smaller, defined work zone is easier to barricade, easier to keep clear of pedestrians, and easier to restore.

6. It moves at a predictable pace

EPA cites a typical bursting rate of about 100 feet per hour, with most single runs best kept under roughly 750 feet. Actual schedules also depend on access, bypass setup, service reconnections, and testing, so ask for a written sequence. For a closer look at the lining-versus-bursting decision, see our post on when commercial pipe bursting in Georgia makes more sense than lining.

NGI Trenchless Pipe & Sewer Repair shows the difference between a broken pipe and a new replacement.

A Georgia Example: Dalton

EPA’s fact sheet includes a Georgia case. In 2001, Dalton budgeted $1.2 million to replace 11,000 feet of clay sanitary sewer. Over about six months, roughly 3,300 feet was replaced with HDPE pipe using a Vermeer Air Impactor paired with a horizontal directional drill. EPA reports the drill rod was able to push through root intrusion in the old pipes and that the contractor averaged about 3 feet per minute. The budget also covered trench-and-replace work, so the figure isn’t a bursting price. It’s a useful example of a Georgia utility choosing bursting for clay lines, though methods and costs have changed since 2001.

Where Pipe Bursting Isn’t the Right Fit

A good contractor tells you when bursting is the wrong tool. EPA lists conditions where it’s not favorable, plus a separate EPA memo on asbestos-cement pipe.

SystemWhat It IsWhere It FitsWatch-Outs
Water plugs and chemical groutRapid-set plugs or injected grout that stop active leaksStopping infiltration, usually before a lining or coating goes inNASSCO says grout belongs on a structurally sound manhole, and active leaks must be stopped before coatings
Cementitious linerCement- or geopolymer-based mortar that is troweled, sprayed, or spincast onto the wallsRestoring walls and bench; NASSCO gives a typical single-coat range of 0.5 to 1 inchNot applied in freezing weather; sulfide resistance must be specified where corrosion is a concern
Polymeric coatingEpoxy, polyurethane, or polyurea sprayed, spincast, or troweled onCorrosion protection and sealing, with thickness set by the substrate and loadsSurface prep and moisture state drive success; testing includes thickness, holiday, and adhesion
Cured-in-place manhole liner (CIPM)A resin-saturated fabric tube or premade liner pressed against the wall with air and curedPartial or full-depth rehabilitation, including chimneysNeeds a prepared, leak-free surface and a flow bypass or flow-through tube
Panel liners, inserts, and poured-in-place linersHDPE or PVC panels, fiberglass inserts, or a new concrete wall formed inside the old oneStructural rehabilitation of badly deteriorated manholesUsed where the old structure can't carry the loads; NASSCO calls for a registered engineer's design
Chimney sealsMechanical, applied polymer, or cured-in-place seals at the frame and coneStopping infiltration at the top of the structureSequence matters when combined with a liner or coating
Frame, cover, and adjustment ringsNew castings and rings set to gradeRocking covers, cracked frames, and traffic damageCastings should meet load ratings such as AASHTO M306

 The asbestos-cement point is especially important for public works. In a 2022 EPA memo on AC pipe replacement, EPA notes that AC pipe was used extensively for water, sanitary sewer, and storm drain lines. It lists open trench and a trenchless method called close tolerance pipe slurrification as approved replacement methods, and it lists pipe bursting and pipe breaking as not approved. Before any bursting project, confirm what material your line is made of.

Bursting also needs bypass and pits.  EPA says the existing flow must be bypassed or diverted, and an insertion pit usually has to be dug unless a manhole-to-manhole method is used. Plan for both from the start.

What a Bursting Project Involves

EPA’s general steps give you a useful checklist for reviewing a proposal:

  1. Gather the pipe’s history and view it with closed-circuit TV. NGI’s mainline camera pipe inspections fit this first step.
  2. Install the flow bypass.
  3. Construct access pits if needed.
  4. Disconnect services.
  5. Cut or remove impediments, such as repair couplings, valves, or thick concrete encasement.
  6. Burst the old pipe and pull in the new pipe.
  7. Pressure-test the pipe.
  8. Tie into the existing system, reconnect services, and remove the bypass.

EPA also notes that ground-penetrating radar may be needed to locate undocumented utilities, and that bursting work should be coordinated with utility work by other agencies. Unexpected conditions, such as abandoned utilities that aren’t on the records, can increase both time and risk.

NGI Trenchless Pipe & Sewer Repair equipment cleaning a sewer manhole in a parking lot.

What Drives the Cost

Rather than quote prices from a fact sheet written in 2006, here are the factors EPA lists as driving a project’s cost: the diameter and material of the old and new pipe, the length, removal of burst fragments, specific defects, depth, access manhole locations, the number of extra pits, other utilities to avoid, flow bypass, the number of service connections to reinstate, directional changes at manholes, and ground conditions. For NGI’s own cost guidance for commercial and municipal work, see its trenchless sewer repair cost guide.

How to Evaluate a Bursting Contractor

  • Confirm licensing. NGI holds Georgia Utility Contractor License UC 302559. You can verify a license in the state’s licensing portal.
  • Ask about prequalification. NGI is prequalified with the Georgia Department of Transportation (Vendor ID 19371). NGI’s project page describes that process as state-level vetting of financial stability, safety record, bonding capacity, and technical capability, so ask for the details you need.
  • Verify inspection credentials. NASSCO’s PACP certification is valid for three years and must be renewed, and NASSCO runs a public directory where you can look up individual certification.
  • Ask for the bypass plan, the pit locations, and the material check. Every bursting project depends on these, and a contractor should be able to explain them before work starts.
  • Ask for a written sequence and documentation. That includes pre-work CCTV, pressure testing, and post-work records.

Public works buyers can also see how NGI handles on-call municipal work on its Johns Creek and Jasper project pages, and in our guide to choosing an on-call trenchless contractor in Georgia. Facility managers can start with our industrial services page, and storm drain and trenchless sewer repair services cover related work.

Frequently Asked Questions

What are the main benefits of pipe bursting?

Pipe bursting installs a new pipe without a continuous trench. According to EPA, its advantages include limited surface disruption, the ability to burst pipes in poor condition, a wide range of pipe sizes, and the ability to up-size. It typically increases capacity more than other trenchless rehabilitation methods.

How long can a pipe bursting run be?

EPA says bursting is most appropriate for single runs up to about 750 feet, though straight pulls of more than 1,000 feet have been done. Friction and the space available to lay out the new pipe are the main limits.

Can pipe bursting increase pipe size?

Yes. EPA says replacing with a larger pipe is possible, and that going up at least one size is usually advisable. How much you can up-size depends on the surrounding soil, and larger up-sizings cause more ground movement.

What pipe materials can be burst?

EPA says most existing pipe materials other than HDPE can be burst, while some ductile iron and reinforced concrete can be very difficult. Asbestos-cement pipe is a special case: EPA says bursting or breaking it makes it friable and doesn’t comply with the Asbestos NESHAP.

Does the line have to be taken out of service?

Yes. EPA says the rehabilitated segment must be taken out of service, with flows blocked or rerouted around the work area, and services are reconnected afterward.

Does NGI offer pipe bursting?

Yes. NGI offers pipe bursting alongside CIPP lining, and it starts with a CCTV inspection so the method is chosen from the pipe’s actual condition. Call (404) 860-2022 to discuss your line.

Pipe bursting earns its place when a line has to be replaced, the old pipe can’t be trusted, and the site can’t tolerate a long trench. It isn’t right for every line, and a good contractor will say so. Start with an inspection, confirm the pipe material and the soil, and plan the bypass early.

NGI Trenchless Pipe & Sewer Repair: Trenchless Rehabilitation for Facilities and Municipalities

NGI Trenchless Pipe & Sewer Repair is a NASSCO-certified trenchless contractor serving commercial, industrial, municipal, and residential clients across Metro Atlanta and North Georgia. It holds Georgia Utility Contractor License UC 302559 and is prequalified with the Georgia Department of Transportation (Vendor ID 19371).

Contact us today to talk through your line and your options.

Planning a full-line replacement?

Start with a CCTV inspection. It shows the pipe’s real condition, so the right method, bursting, lining, or open-cut, is chosen from evidence.

Request a Project Assessment | (404) 860-2022